Heaters
Immersion, flanged, circulation, process-air, band, and floor heating for nearly every industrial and commercial application.
Anderson-Bolds supplies electric heaters from Watlow, Process Technology, BriskHeat, Q'Mark, Danfoss, and Convectronics — including immersion/screw-plug, flanged, and circulation heaters for liquids, process-air heaters, and electric floor/snow-melt systems. Most stock immersion heaters ship the same day, and our application engineers can size watt density to your tank and medium so the sheath doesn't scorch the fluid.

Watlow BEN10N6C, Immersion Heater, 2.5 kw, 120/240 VAC, Alloy 800 Elements, NO Thermostat

Watlow BEN10N6C2, Immersion Heater, 2.5 kw, 120/240 VAC, Alloy 800 Elements, 30-250 Tstat

Watlow BEN10N6C3, Immersion Heater, 2.5 kw, 120/240 VAC, Alloy 800 Elements, 175-550 Tstat

Watlow BEN10N6S, Immersion Heater, 2.5 kw, 120/240 VAC, Alloy 800 Elements, NO Thermostat

Watlow BEN10N6S2, Immersion Heater, 2.5 kw, 120/240 VAC, Alloy 800 Elements, 30-250 Tstat

Watlow BEN10N6S3, Immersion Heater, 2.5 kw, 120/240 VAC, Alloy 800 Elements, 175-550 Tstat

Watlow BEN15A6C, Immersion Heater, 3 kw, 120/240 VAC, Alloy 800 Elements, NO Thermostat

Watlow BEN15A6C2, Immersion Heater, 3 kw, 120/240 VAC, Alloy 800 Elements, 30-250 Tstat

Watlow BEN15A6C3, Immersion Heater, 3 kw, 120/240 VAC, Alloy 800 Elements, 175-550 Tstat

Watlow BEN15A6S, Immersion Heater, 3 kw, 120/240 VAC, Alloy 800 Elements, NO Thermostat

Watlow BEN15A6S2, Immersion Heater, 3 kw, 120/240 VAC, Alloy 800 Elements, 30-250 Tstat

Watlow BEN15A6S3, Immersion Heater, 3 kw, 120/240 VAC, Alloy 800 Elements, 175-550 Tstat

Watlow BEN4G6C, Immersion Heater, 1 kw, 120/240 VAC, Alloy 800 Elements, NO Thermostat

Watlow BEN4G6C2, Immersion Heater, 1 kw, 120/240 VAC, Alloy 800 Elements, 30-250 Tstat

Watlow BEN4G6C3, Immersion Heater, 1 kw, 120/240 VAC, Alloy 800 Elements, 175-550 Tstat

Watlow BEN4G6S, Immersion Heater, 1 kw, 120/240 VAC, Alloy 800 Elements, NO Thermostat

Watlow BEN4G6S2, Immersion Heater, 1 kw, 120/240 VAC, Alloy 800 Elements, 30-250 Tstat

Watlow BEN4G6S3, Immersion Heater, 1 kw, 120/240 VAC, Alloy 800 Elements, 175-550 Tstat

Watlow BEN6G6C, Immersion Heater, 1.5 kw, 120/240 VAC, Alloy 800 Elements, NO Thermostat

Watlow BEN6G6C2, Immersion Heater, 1.5 kw, 120/240 VAC, Alloy 800 Elements, 30-250 Tstat

Watlow BEN6G6C3, Immersion Heater, 1.5 kw, 120/240 VAC, Alloy 800 Elements, 175-550 Tstat

Watlow BEN6G6S, Immersion Heater, 1.5 kw, 120/240 VAC, Alloy 800 Elements, NO Thermostat

Watlow BEN6G6S2, Immersion Heater, 1.5 kw, 120/240 VAC, Alloy 800 Elements, 30-250 Tstat

Watlow BEN6G6S3, Immersion Heater, 1.5 kw, 120/240 VAC, Alloy 800 Elements, 175-550 Tstat

Watlow BEN8J6C, Immersion Heater, 2 kw, 120/240 VAC, Alloy 800 Elements, NO Thermostat

Watlow BEN8J6C2, Immersion Heater, 2 kw, 120/240 VAC, Alloy 800 Elements, 30-250 Tstat

Watlow BEN8J6C3, Immersion Heater, 2 kw, 120/240 VAC, Alloy 800 Elements, 175-550 Tstat

Watlow BEN8J6S, Immersion Heater, 2 kw, 120/240 VAC, Alloy 800 Elements, NO Thermostat

Watlow BEN8J6S2, Immersion Heater, 2 kw, 120/240 VAC, Alloy 800 Elements, 30-250 Tstat

Watlow BEN8J6S3, Immersion Heater, 2 kw, 120/240 VAC, Alloy 800 Elements, 175-550 Tstat

Watlow BGN711C6C, Immersion Heater, 3 kw, 120/240 VAC/1 phase, Alloy 800 Elements

Watlow BGN711C6C4, Immersion Heater, 3 kw, 120/240 VAC/1 phase, Alloy 800 Elements, 30-110 Tstat

Watlow BGN711C6C5A, Immersion Heater, 3 kw, 120/240 VAC/1 phase, Alloy 800 Elements, 60-250 Tstat

Watlow BGN711C6C7A, Immersion Heater, 3 kw, 120/240 VAC/1 phase, Alloy 800 Elements, 100-550 Tstat

Watlow BGN711C6S, Immersion Heater, 3 kw, 120/240 VAC/1 phase, Alloy 800 Elements,

Watlow BGN711C6S4, Immersion Heater, 3 kw, 120/240 VAC/1 phase, Alloy 800 Elements, 30-110 Tstat

Watlow BGN711C6S5A, Immersion Heater, 3 kw, 120/240 VAC/1 phase, Alloy 800 Elements, 60-250 Tstat

Watlow BGN711C6S7A, Immersion Heater, 3 kw, 120/240 VAC/1 phase, Alloy 800 Elements, 100-550 Tstat

Watlow BGN713E6C, Immersion Heater, 3 kw, 120/240 VAC/1 phase, Alloy 800 Elements

Watlow BGN713E6C4, Immersion Heater, 3 kw, 120/240 VAC/1 phase, Alloy 800 Elements, 30-110 Tstat

Watlow BGN713E6C5A, Immersion Heater, 3 kw, 120/240 VAC/1 phase, Alloy 800 Elements, 60-250 Tstat

Watlow BGN713E6C7A, Immersion Heater, 3 kw, 120/240 VAC/1 phase, Alloy 800 Elements, 100-550 Tstat

Watlow BGN713E6S, Immersion Heater, 3 kw, 120/240 VAC/1 phase, Alloy 800 Elements,

Watlow BGN713E6S4, Immersion Heater, 3 kw, 120/240 VAC/1 phase, Alloy 800 Elements, 30-110 Tstat

Watlow BGN713E6S5A, Immersion Heater, 3 kw, 120/240 VAC/1 phase, Alloy 800 Elements, 60-250 Tstat

Watlow BGN713E6S7A, Immersion Heater, 3 kw, 120/240 VAC/1 phase, Alloy 800 Elements, 100-550 Tstat

Watlow BGN715C6C, Immersion Heater, 4 kw, 120/240 VAC/1 phase, Alloy 800 Elements

Watlow BGN715C6C4, Immersion Heater, 4 kw, 120/240 VAC/1 phase, Alloy 800 Elements, 30-110 Tstat
Heaters — questions buyers ask
How do I size an immersion heater?
Calculate the kW from the fluid volume, the temperature rise, and the time to reach setpoint, then check the watt density against the medium so the sheath stays below the fluid's scorch point. Use our heater sizing tool or send your tank details to an application engineer.
What sheath material should I use?
Use Incoloy/INCOLOY-800 for most water and process fluids and high temperatures, copper for clean water at lower temperatures, and 316 stainless for mildly corrosive solutions. Match the sheath to the medium to avoid premature failure.
Can you supply a custom or flanged immersion heater?
Yes. Flanged and circulation heaters are typically configured to the application (kW, voltage, flange size, thermowell, control). Add the item to an RFQ and our reps will spec and quote it.






