UPS & Power
Single- and three-phase uninterruptible power systems and DC power systems for protecting critical loads.
Anderson-Bolds is an authorized Toshiba UPS distributor, supplying single-phase tower and rackmount UPS and three-phase online double-conversion UPS, plus HDR/AMETEK DC power systems. Online double-conversion topology gives the cleanest power for sensitive industrial and IT loads.

Toshiba 1000 Series 1.0 kVA UPS, 120V Tower

Toshiba T1S0A1000AXAR2 1.0 KVA UPS, 120v in/out, Rackmount, 2U

Toshiba T1S0A2000AXA 2.0 KVA UPS, 120v in/out, Tower

Toshiba T1S0A2000AXAR2 2.0 KVA UPS, 120v in/out, Rackmount, 2U

Toshiba T1S0A6000GXG 6 KVA UPS, 208-240v in/out, Tower

Toshiba T1S0A6000GXGR6 6 KVA UPS, 208-240v in/out, Rackmount, 6U

Toshiba T1S2A6000GXG 6 KVA UPS, 208-240v in/out, Tower

Toshiba T1S2A6000GXGR6 6 KVA UPS, 208-240v in/out, Rackmount, 6U

Toshiba T1S4A5200GXG 5.2 KVA UPS, 208/240v in/out, Tower

Toshiba T1S4A5200GXGR6 5.2 KVA UPS, 208-240v in/out, Rackmount, 6U

Toshiba T1S4A6000GXG 6 KVA UPS, 208-240v in/out, Tower

Toshiba T1S4A6000GXGR6 6 KVA UPS, 208-240v in/out, Rackmount, 6U
Toshiba 1000 series Battery Module for 6 KVA Rackmount UPS. 208/240 in/out. 3U

Toshiba UT1A1A010C6 1.0 KVA UPS, 120v in/out, Tower - OBSOLETE
Toshiba UT1A1A010C6RKB2 1.0 KVA UPS, 120v in/out, Rackmount, 2U - OBSOLETE

Toshiba UT1A1A010C6T 1.0 KVA UPS, 120v in/out, Tower with I.T. - OBSOLETE

Toshiba UT1A1A015C6 1.5 KVA UPS, 120v in/out, Tower
Toshiba UT1A1A015C6RKB2 1.5 KVA UPS, 120v in/out, Rackmount, 2U

Toshiba UT1A1A020C6 2.0 KVA UPS, 120v in/out, Tower - OBSOLETE
Toshiba UT1A1A020C6RKB2 2.0 KVA UPS, 120v in/out, Rackmount, 2U - OBSOLETE

Toshiba UT1A1A030C6 3.0 KVA UPS, 120v in/out, Tower
Toshiba UT1A1A030C6RKB2 3.0 KVA UPS, 120v in/out, Rackmount, 2U

Toshiba UT1E1E010C6 1.0 KVA UPS, 230v in/out, Tower
Toshiba UT1E1E010C6RKB2 1.0 KVA UPS, 230v in/out, Rackmount, 2U

Toshiba UT1E1E015C6 1.5 KVA UPS, 230v in/out, Tower
Toshiba UT1E1E015C6RKB2 1.5 KVA UPS, 230v in/out, Rackmount, 2U

Toshiba UT1E1E020C6 2.0 KVA UPS, 230v in/out, Tower
Toshiba UT1E1E020C6RKB2 2.0 KVA UPS, 230v in/out, Rackmount, 2U

Toshiba UT1E1E030C6 3.0 KVA UPS, 230v in/out, Tower
Toshiba UT1E1E030C6RKB2 3.0 KVA UPS, 230v in/out, Rackmount, 2U
Toshiba UT1G1G060C6RKB3 6.0 KVA UPS, 208/240v in/out, Rackmount, 3U
Toshiba UT1G1G060C6RKB3 6.0 KVA UPS, 208/240v in/out, Rackmount, 3U plus UT1-BR-0607 Battery Module

Toshiba UT1G2L024C6TP1 2.4 KVA UPS, 208/240v in/out, Tower with Isolation Tranformer

Toshiba 1000 Series RACKMOUNT RAIL KIT

Toshiba 1000 Series remote Contact Card Option.
UPS & Power — questions buyers ask
What size UPS do I need?
Add up the running watts (or VA) of the connected load, add ~25% headroom, then choose a UPS whose VA/Watt rating exceeds that. For runtime, match the battery to the minutes you need at that load.
What is online double-conversion?
The load always runs from the inverter, which is continuously fed by the rectifier/battery, so there is zero transfer time and the output is fully regenerated — the best protection for sensitive equipment.