Valves
Solenoid, coaxial, control, regulating, and scientific valves plus specialty ball valves for flow and process control.
Anderson-Bolds stocks and reps solenoid and process valves from Parker, ASCO, Coax, Valcor, and Webstone — 2-way and 3-way solenoid valves, high-pressure coaxial valves, control and regulating valves, and specialty ball valves. Tell us the media, port size, pressure, and coil voltage and we'll match the valve and Cv.

Parker 20CC02EV4C4A, 1/8 inch 2-way Valve, 0-390 psi, 12vdc, NC, Nema 4

Parker 20CC02EV4D6A, 1/8 inch 2-way Valve, 0-390 psi, 12vdc, NC, Nema 7

Parker 20CC02GV4C4A, 1/8 inch 2-way Valve, 0-255 psi, 12vdc, NC, Nema 4

Parker 20CC02GV4D6A, 1/8 inch 2-way Valve, 0-255 psi, 12vdc, NC, Nema 7

Parker 20CC02LV4C4A, 1/8 inch 2-way Valve, 0-130 psi, 12vdc, NC, Nema 4

Parker 20CC02LV4D6A, 1/8 inch 2-way Valve, 0-130 psi, 12vdc, NC, Nema 7

Parker 20CC02MV4C4A, 1/8 inch 2-way Valve, 0-100 psi, 12vdc, NC, Nema 4

Parker 20CC02MV4D6A, 1/8 inch 2-way Valve, 0-100 psi, 12vdc, NC, Nema 7

Parker 20CC02PV4C4A, 1/8 inch 2-way Valve, 0-60 psi, 12vdc, NC, Nema 4

Parker 20CC02PV4D6A, 1/8 inch 2-way Valve, 0-60 psi, 12vdc, NC, Nema 7

Parker 20CC02QV4C4A, 1/8 inch 2-way Valve, 0-30 psi, 12vdc, NC, Nema 4

Parker 20CC02QV4D6A, 1/8 inch 2-way Valve, 0-30 psi, 12vdc, NC, Nema 7

Parker 20CF02EV4C4A, 1/8 inch 2-way Valve, 0-230 psi, 12vdc, NO, Nema 4

Parker 20CF02EV4D6A, 1/8 inch 2-way Valve, 0-230 psi, 12vdc, NO, Nema 7

Parker 20CF02LV4C4A, 1/8 inch 2-way Valve, 0-80 psi, 12vdc, NO, Nema 4

Parker 20CF02LV4D6A, 1/8 inch 2-way Valve, 0-80 psi, 12vdc, NO, Nema 7

Parker 30CC02EV4C4A, 1/8 inch 3-way Valve, 0-200 psi, 12vdc, NC, Nema 4

Parker 30CC02EV4D6A, 1/8 inch 3-way Valve, 0-200 psi, 12vdc, NC, Nema 7

Parker 30CC02GV4C4A, 1/8 inch 3-way Valve, 0-130 psi, 12vdc, NC, Nema 4

Parker 30CC02GV4D6A, 1/8 inch 3-way Valve, 0-130 psi, 12vdc, NC, Nema 7

Parker 30CC02MV4C4A, 1/8 inch 3-way Valve, 0-50 psi, 12vdc, NC, Nema 4

Parker 30CC02MV4D6A, 1/8 inch 3-way Valve, 0-50 psi, 12vdc, NC, Nema 7

Parker 30CF02EV4C4A, 1/8 inch 3-way Valve, 0-230 psi, 12vdc, NO, Nema 4

Parker 30CF02EV4D6A, 1/8 inch 3-way Valve, 0-230 psi, 12vdc, NO, Nema 7

Parker 30CU02EV4C4A, 1/8 inch 3-way Valve, 0-150 psi, 12vdc, Uni, Nema 4

Parker 30CU02EV4D6A, 1/8 inch 3-way Valve, 0-150 psi, 12vdc, Uni, Nema 7

Parker 30CU02GV4C4A, 1/8 inch 3-way Valve, 0-100 psi, 12vdc, Uni, Nema 4

Parker 30CU02GV4D6A, 1/8 inch 3-way Valve, 0-100 psi, 12vdc, Uni, Nema 7

PARKER 2-Way Solenoid Valve 71216SN1GL00N0C111C1, 12VDC, 1/8 NPT, NC, 0-1250psi, SS

PARKER 3-Way Solenoid Valve 71315SN1ENJ1N0L111C1, 12VDC, 1/8 NPT, NC, 0-250psi, SS

PARKER 3-Way Solenoid Valve 71395SN1ENJ1NOL111C1, 12VDC, 1/8 NPT, NC, 0-250psi, SS

PARKER 3-Way Solenoid Valve 71395SN2GNJ1N0C111C1, 12VDC, 1/4 NPT, NC, 0-250psi, SS

Parker GP23 coil, 12 vdc for Parker GP valves
Brands in Valves
Valves — questions buyers ask
What's the difference between a 2-way and 3-way solenoid valve?
A 2-way valve has one inlet and one outlet and simply opens or closes a line. A 3-way valve has three ports and switches flow between two paths — used to pressurize/exhaust an actuator or divert flow.
How do I pick the right Cv?
Cv is the flow coefficient: the higher the Cv, the more flow at a given pressure drop. Size it from your required flow rate and allowable pressure drop for the media — our team can calculate it from your conditions.


